SpeedFreakLS1
SpeedFreakLS1
  • Видео 90
  • Просмотров 468 845
Finding Mystery Life Growing Way Inside This Mine ?!?!
#abandonedmines #exploringabandonedmines #mineexploring #mineexploration #mines #minesexplorers #fidgetspinnerexplorers #abandoned #fyp #mineexploring #undergroundexploration #abandonedmines #exploringabandonedmines
00:00 - Intro
00:30 - Entering the First Abandoned Mine
07:24 - Exploring the Second Abandoned Mine
16:22 - Discovering Mystery Flower/Fungus/Plant????? NO LIGHT!!!!
17:58 - A second look at the Mystery Flower/Fungus/Plant?????
19:07 - Dropping down the Ore Chute
20:53 - Finding a Dead Rabbit Deep Inside this Mine
24:24 - Discovering an old SAFE
25:33 - Discovering a gated deep abandoned Mine Shaft
26:53 - Stuck due to the SNOW
29:39 - Entering an Abandoned Haulage Tunnel
Просмотров: 203

Видео

Abandoned Mine Exploration May 2024 Teaser (4K)
Просмотров 560Месяц назад
#AbandonedMineExploration #MineExplorers #fidgetspinnerexplorers #interestingisthewordofthevideo #fyp #abandonedplaces #abandoned #mines Videos to come out within a month!
138,000 Volt Substation tour with DRONE!
Просмотров 5 тыс.5 месяцев назад
I love to learn and to educate others on the small fraction of what I know. I hope these videos will keep people safe and make them smarter about high voltage. There are lifetimes of knowledge with each piece of equipment shown in these videos. I only touch the surface. I am always learning and want others to learn along with me. I am not a professional speaker by far so sorry for any grammatic...
STANDING on a 138,000 Volt Transformer!
Просмотров 6 тыс.5 месяцев назад
*234 MVA 138kV to 35kV Y Y D Transformer. I love to learn and to educate others on the small fraction of what I know. I hope these videos will keep people safe and make them smarter about high voltage. There are lifetimes of knowledge with each piece of equipment shown in these videos. I only touch the surface. I am always learning and want others to learn along with me. I am not a professional...
138 kV High Voltage Substation Walk
Просмотров 27 тыс.6 месяцев назад
In this video I do an explanation video a punch list walk of a near complete substation. Note there are lifetimes of information for each of these specific devices. I only know a small fraction about each.
Abandoned Mines, 100 TON Ore Furnace, Exploratory Drift!
Просмотров 4137 месяцев назад
#MineExplorers #fidgetspinnerexplorers #coolisthewordofthevideo #fyp #MineExploring #undergroundexploration #AbandonedMines #exploringabandonedmines 0:00 - Intro 0:09 - Spider Mine outcropping 00:39 - Ghost Town Mine Site 1:00 - 100 TON furnace 06:24 - Porkburg Mine 17:20 - Gooding Mine
Abandoned Mines, SNAKE and Crazy Abandoned Caretakers House!!
Просмотров 8658 месяцев назад
#MineExplorers #fidgetspinnerexplorers #coolisthewordofthevideo #fyp #MineExploring #undergroundexploration #AbandonedMines #ExploringAbandonedMines 0:00 - Intro 0:08 - First Head frame 03:57 - SNAKE! 04:52 - Overlanding 06:26 - Shower Review 07:02 - Mine Shaft 14:11 - Abandoned Adit Mine 20:06 - Crazy Abandoned Caretaker House! 29:11 - Rabbit and NVG's
I'm in a book!! Stories from the Cerro Gordo Ghost Town Caretaker!
Просмотров 48010 месяцев назад
#MineExplorers #fidgetspinnerexplorers #coolisthewordofthevideo #fyp #MineExploring #undergroundexploration #AbandonedMines #exploringabandonedmines THANK YOU for Supporting Robert!!! Mail Check or Money Order to: Robert Desmarais 596 US Highway 395 North Unit 17 Gardnervile, NV 89410 $25.00 per book plus $5.00 S/H.
High Voltage 345,000 Volt Switch closing at NIGHT!
Просмотров 2,3 тыс.Год назад
High Voltage 345kV Air Switch closing in. If this was a load break switch, we would probably time it a little better on the closing side. I am so freaking sorry this was not in 4k like everything else. No excuse, I kicked my own butt over it. #DisconnectorSwitching #ElectricArc #sparks #highvoltage
Abandoned Les Crow Mine Exploration
Просмотров 293Год назад
#MineExplorers #fidgetspinnerexplorers #coolisthewordofthevideo #fyp #MineExploring #undergroundexploration #AbandonedMines #ExploringAbandonedMines 0:00 - Intro 8:46 - Electrical Panels 11:11 - First Ore Car 19:39 - First Internal Shaft 25:20 - Second Internal Shaft 37:46 - Ore Track Confusion 40:39 - Headed up the Decline
Abandoned Mine Exploration May 2023 Teaser
Просмотров 318Год назад
#MineExplorers #fidgetspinnerexplorers #coolisthewordofthevideo #fyp Main video to come out within a month!
4k Close up of Snow/Ice on Wind Turbine Blades- Perfect snowy morning
Просмотров 1,5 тыс.Год назад
4k Close up of Snow/Ice on Wind Turbine Blades- Perfect snowy morning
345kV Substation Drone Flyover (Teaser)
Просмотров 613Год назад
345kV Substation Drone Flyover (Teaser)
Abandoned Underground Mine Exploration - New Mexico 2.0
Просмотров 3,1 тыс.2 года назад
Abandoned Underground Mine Exploration - New Mexico 2.0
Abandoned Underground Mine Exploration - New Mexico
Просмотров 8 тыс.2 года назад
Abandoned Underground Mine Exploration - New Mexico
35kV Underground XLPE High Voltage Cable
Просмотров 26 тыс.3 года назад
35kV Underground XLPE High Voltage Cable
345 kV Transformer Issues?? Part 2!!!!
Просмотров 17 тыс.3 года назад
345 kV Transformer Issues?? Part 2!!!!
345 kV Substation Interlocks - Protecting Substation Equipment and YOU
Просмотров 47 тыс.3 года назад
345 kV Substation Interlocks - Protecting Substation Equipment and YOU
345 kV Transformer Issues?? Part 1
Просмотров 22 тыс.3 года назад
345 kV Transformer Issues?? Part 1
COVID-19 forced us to cancel our wedding
Просмотров 1,9 тыс.3 года назад
COVID-19 forced us to cancel our wedding
Cerro Gordo Belshaw Union Shaft 900ft SIDE VIEW
Просмотров 4,5 тыс.3 года назад
Cerro Gordo Belshaw Union Shaft 900ft SIDE VIEW
Cerro Gordo Belshaw Union Shaft 900ft DOWN VIEW
Просмотров 2,4 тыс.3 года назад
Cerro Gordo Belshaw Union Shaft 900ft DOWN VIEW
345 kV Transformer insulator installation
Просмотров 6 тыс.3 года назад
345 kV Transformer insulator installation
Cerro Gordo Union Mine Shaft Exploration
Просмотров 203 тыс.5 лет назад
Cerro Gordo Union Mine Shaft Exploration
Jet Skis in the pond and shooting the .50 cal
Просмотров 1585 лет назад
Jet Skis in the pond and shooting the .50 cal
Barrett M82A1 first time out
Просмотров 8426 лет назад
Barrett M82A1 first time out
Hurricane Harvey 2017
Просмотров 4396 лет назад
Hurricane Harvey 2017
34.5 kV Substation Walkthrough
Просмотров 35 тыс.6 лет назад
34.5 kV Substation Walkthrough
Hurricane Harvey 2017 neighbors evacuating
Просмотров 3836 лет назад
Hurricane Harvey 2017 neighbors evacuating

Комментарии

  • @abramheinrichs9853
    @abramheinrichs9853 8 дней назад

    I like to find one of those.

  • @magnuspyro
    @magnuspyro 10 дней назад

    Good catch on the Atlas explosives. At first they looked like they were in good shape until you showed the goop. I am sure that part of your video got the ATF's attention. While nobody is likely to find that case, that's a 'no no'.

  • @damorafik
    @damorafik 28 дней назад

    Thank you very much for this presentation, very much appreciated 👌

  • @tronskifpv
    @tronskifpv Месяц назад

    looking good!

  • @hogofwar0
    @hogofwar0 Месяц назад

    careful

  • @EvergreenLP
    @EvergreenLP Месяц назад

    wow that's crazy! I'm stoked! 💪👍

  • @masatofujimura4865
    @masatofujimura4865 Месяц назад

    What an absolute fantastic walk through video. It’s always been my dream to have someone talk me through substation equipment in real life. This is about as close as it can get. Cannot thank you enough. You got yourself a new subscriber!

  • @shannonveras1816
    @shannonveras1816 2 месяца назад

    you know those NM underground mines were never properly deconaminated/contained and still contain levels or uranium

  • @gaildimick1831
    @gaildimick1831 2 месяца назад

    I seen an extra head gasket hanging off the rafters. Great OWS engine.

  • @gaildimick1831
    @gaildimick1831 2 месяца назад

    Looks like the same one the 86 year old man started. Nice

  • @gaildimick1831
    @gaildimick1831 2 месяца назад

    Had to watch again. Not many can do that at 86. Most are in the nursing home or 6 feet under.

  • @brianbooker5704
    @brianbooker5704 3 месяца назад

    What company do you work for?

  • @mrigankadas1093
    @mrigankadas1093 4 месяца назад

    Where is this Sub located at ?

  • @voxle3976
    @voxle3976 4 месяца назад

    Really want to join you on a mine exploration!!! Idk how to reach put to you otherwise but if we could message somehow that would be awesome!!! Spamming this in hopes you see one, sorry.

  • @voxle3976
    @voxle3976 4 месяца назад

    Really want to join you on a mine exploration!!! Idk how to reach put to you otherwise but if we could message somehow that would be awesome!!!

  • @voxle3976
    @voxle3976 4 месяца назад

    Really want to join you on a mine exploration!!! Idk how to reach put to you otherwise but if we could message somehow that would be awesome!!!

  • @ecaparts
    @ecaparts 4 месяца назад

    I would totally push the Green button to start. I am so use to Green to go, Red for stop…

  • @andrewtr001
    @andrewtr001 4 месяца назад

    So im guessing this means that plant that we've been watching is finally online

  • @mxslick50
    @mxslick50 4 месяца назад

    Why are they closing in several breakers with failed trip coils?

    • @spdfreakls1
      @spdfreakls1 4 месяца назад

      Gold star! You successfully found 1 of 2 issues I left in that.

    • @mxslick50
      @mxslick50 4 месяца назад

      @@spdfreakls1 Was the second one "Undervoltage Disabled"?

    • @spdfreakls1
      @spdfreakls1 4 месяца назад

      @@mxslick50 good find but no. Keep looking!

    • @mxslick50
      @mxslick50 4 месяца назад

      @@spdfreakls1 Relay test switches I, J, opened on 11-T1

    • @spdfreakls1
      @spdfreakls1 4 месяца назад

      @@mxslick50 Nailed it! Man I need to make these things harder!

  • @dr.deborahkatharinestevens318
    @dr.deborahkatharinestevens318 4 месяца назад

    Absolutely fascinating, thank you very much.👍

  • @glenmartin2437
    @glenmartin2437 4 месяца назад

    Thanks for the video. I worked in a mining/milling operation years ago. 600 volts max. Thanks again.

  • @stormeagle28
    @stormeagle28 5 месяцев назад

    Here in Germany and Europe altogether every official shits his pants when you talk about flying drones close to substations or power lines... like a single small drone will surely cause a nation-wide power outage if it collides with a single power line.

    • @spdfreakls1
      @spdfreakls1 4 месяца назад

      that is funny. Its like a bird on a wire, nothing happens.

  • @markward7556
    @markward7556 5 месяцев назад

    With regards to power factor control, I have a good example of how this works based on a 120v. electric motor. This is a 2 hp motor that draws 12 amps line current with no load. By parallel connection of a 180 uf capacitor, my line amperage drops to about 3A. The capacitor cancels the inductive portion of the current drawn from the AC line by the motor.

  • @UQRXD
    @UQRXD 5 месяцев назад

    What is the loss like ?

  • @pedromorgado7222
    @pedromorgado7222 5 месяцев назад

    Can you please tell me how to calculate, the fuses in the primary for a transformer 600 volts, 3 phases, 75 KVA? Primary Delta and secondary Why. Thanks.

  • @enzojolt
    @enzojolt 5 месяцев назад

    Is this in mogollon?

  • @MrErichonda30
    @MrErichonda30 5 месяцев назад

    Are you a superintendent or engineer?

    • @spdfreakls1
      @spdfreakls1 5 месяцев назад

      Neither sir! Just helping out where I can and learning every day!

  • @brucewinningham4959
    @brucewinningham4959 5 месяцев назад

    As a part-time student of Electrical & Electronics Engineering, I have t three QUESTIONS Please. (1) Why are the Transformers "Humming" if there is no load on them? (2) Is it periodically required to change the Transformer Oil like the Motor Oil in an Automotive Engine Crankcase? May I assume Probably NOT since there is Normally NO Combustion? (3) What kind of Oil is required if it is Necessary to change the Transformer Oil?

    • @spdfreakls1
      @spdfreakls1 4 месяца назад

      1. The actual hum is the core laminations vibrating/moving. This is caused by eddie currents. 2. As long as nothing is wrong with the transformer, the oil will be good for 20 plus years. If there are issues, it can be "cleaned" and put back in. If there is a big failure, the oil is replaced. 3. It is clear and tasteless mineral oil.

  • @wesley1983
    @wesley1983 5 месяцев назад

    20:45 cool stuff but unless its calibrated and maintained kind a useless. Just more alarms that people will lift and leave out of service. Send oil samples into a lab. Much better off then guessing if your sampling equipment is correct or not. I wouldn't be using that for tripping.

    • @spdfreakls1
      @spdfreakls1 5 месяцев назад

      Agreed in general to your comment. This unit does self calibrate (it has test gas inside it) and a large bottle of Helium on the outside.

  • @wesley1983
    @wesley1983 5 месяцев назад

    13:44 Why blur the operator?

    • @spdfreakls1
      @spdfreakls1 5 месяцев назад

      Not so much the operator but writing on the steel.

  • @wesley1983
    @wesley1983 5 месяцев назад

    10:02 top right. Do not put shorting terminal blocks in any PT box. Those should be only used in CTs. Someone will put shorting screws in their and blow the ccvt up. Not sure if thats before or after the fuses in there or what but just don't do it. Ask me how I know. Don't tell people to use a screw to hold a sticky back. Rather not have another hole, someone will put a screw in the top. 10yrs no one will care if that sticky back is there. Just make sure you leave enough tail and mark your cables really well. Still doing maintenance on equipment from the 70s.

    • @spdfreakls1
      @spdfreakls1 5 месяцев назад

      Gold star for you sir! We are going to have the shorting bar removed tomorrow!! Great catch!!!

  • @ridefast0
    @ridefast0 5 месяцев назад

    Thank you, that was a treat. This is how retired EEs get their kicks!

  • @brucewinningham4959
    @brucewinningham4959 5 месяцев назад

    What Ores or Minerals were being Mined in this Mine Please?

  • @brucewinningham4959
    @brucewinningham4959 5 месяцев назад

    Curious QUESTION -- What is the likelihood of a Drone flying into a Switch, Transformer or other Device and causing "Arcing, Sparking & Shorts?" Is a Drone Safe to operate in the close Vicinity of a Substation?"

    • @spdfreakls1
      @spdfreakls1 5 месяцев назад

      Good question, the drone is sort of a bird on a wire. Not much will happen, HOWEVER if the drone gets in between phases or the drone gets in between a phase and a ground, there will be an explosion!

  • @matthewbeasley7765
    @matthewbeasley7765 5 месяцев назад

    When there is a set direction of power flow, the normal for a transformer will primary will be delta and the secondary will be wye. The wye connection on the secondary establishes the system ground point. With a conventional power plant, the generator will be wye connected, and the step up will be delta low, wye high. Distribution transformers will have delta high, wye low. Because wind turbine substations work both directions, they need to have a wye connection on both sides. As a generator source on the HV system, the high side needs to be grounded. The low needs a ground, as the wind turbine is usually a 3 wire source. The purpose of the delta tertiary is to establish the ground reference. Since the delta is connected start to finish all the way around the triangle, the sum of VAN, VBN and VCN is forced to be zero. The moment the voltage tries to change, a current will flow in the delta and re-establish the balance.

  • @matthewbeasley7765
    @matthewbeasley7765 5 месяцев назад

    Great video, thanks. I'm surprised you don't have a line ground switch.

  • @John-mj7jn
    @John-mj7jn 5 месяцев назад

    What makes huge transformers better than multiple smaller ones? When I see roads closed to facilitate their transport, I can only imagine the expense.

    • @spdfreakls1
      @spdfreakls1 5 месяцев назад

      Many smaller ones add additional cables, terminations and testing. When you hit about 250MVA you start to swing to it being more expensive. A single 100-250 MVA transformer is more cost effective then many smaller ones. Less of a footprint too.

  • @roberthousedorfii1743
    @roberthousedorfii1743 5 месяцев назад

    Next chance you get, putting in another of these facilities I'd LOVE to the ground system being put in!

  • @SkyChaserCom
    @SkyChaserCom 5 месяцев назад

    Great tour! About the SF6 gas, it's more of a greenhouse gas, not as much ozone depleting. It's about 24,000 times more potent as a greenhouse gas than CO2. The new gas is about 1/10 as potent as SF6 and doesn't last long in the environment.

    • @spdfreakls1
      @spdfreakls1 5 месяцев назад

      This makes sense thanks!

  • @natepeterson34
    @natepeterson34 5 месяцев назад

    Nice video dude! Not a big fan of the mechanical lugs, and am surprised to see them all over this collector substation! Is that common for wherever you live?

  • @xtevesousa
    @xtevesousa 5 месяцев назад

    So when you have a delta input or output you have to ground one of the phases right? (as in Tn-c-s) Do you have any ideia how high the primary/secondary can float in relation to ground if this connection to ground is lost, and would this charge be mostly capacitive coupling from pri/sec or electrostatic charge picked from the lines? Thank you.

    • @matthewbeasley7765
      @matthewbeasley7765 5 месяцев назад

      Wind turbine transformers universally use wye-wye transformers with a delta tertiary. Because they are bi-directional, they need to establish ground on both sides of the system, hence the wye connection on both sides. The delta stabilizes the line to neutral voltage on both sides. Usually the delta will be corner grounded.

  • @TupmaniaTurning
    @TupmaniaTurning 5 месяцев назад

    What an interesting and informative video. Looking forward to a future video of when the station is livened up but I bet you won't be filming quite as close! 😀

  • @VariacManiac
    @VariacManiac 5 месяцев назад

    That's a clean yard! I'm trying to become a sub tech, hope to work on similar equipment someday.

  • @jlvcm
    @jlvcm 5 месяцев назад

    Please, when it starts, you have to show us...

  • @TechOne7671
    @TechOne7671 5 месяцев назад

    Thanks for the video, fascinating stuff. All the best.

  • @hitsmike2046
    @hitsmike2046 5 месяцев назад

    Molecular nitrogen gas has a mass 28 g/mole, while molecular oxygen has a mass of 32 g/mole. Have you ever asked yourself why you can breathe if all the oxygen has sunk to floor? It is because the collision frequency between different gasses is so high that they cannot settle and be stratified by gravity. They continuously collide with each other and mix together. If I measure at the floor, each volume of gas will contain 78% N2, 21% O2, about 1% Ar, and 0.04% CO2. If I stand up I will find the same proportions. If climb mount Everest, there is less total air, but the proportion of these chemically stable elements is the same. In fact I can travel to the edge of space at 80 km, where the gas density is extremely low, but there will still be the same proportions of N2, O2, Ar, and CO2. SF6, like these other species, does not readily react chemically so that it is stable. It then mixes with other gases and maintains its proportion, albeit a small proportion, throughout the atmosphere.

    • @spdfreakls1
      @spdfreakls1 5 месяцев назад

      This was way above my head for the most part but very informative! Thank you for the explanation!

  • @mark111943
    @mark111943 5 месяцев назад

    I enjoyed watching and learning from that, thank you!